ALTIVAR 312 MANUAL DE PROGRAMACION PDF

Retire el ATV del embalaje y compruebe que no presenta daños. .. Consulte el manual del programación (BBV) para una descripción completa del. Manual de programación Altivar® 06/ Contenido .. Altivar 31 (ATV31) es una familia de variadores de velocidad de ~ (c.a.) de frecuencia ajustable. Manual de programación. ATV Manual de programación Manual de programación · altivar-machine-atv ATV Manual de programación.

Author: Bazuru Arale
Country: Azerbaijan
Language: English (Spanish)
Genre: Business
Published (Last): 15 April 2007
Pages: 205
PDF File Size: 17.11 Mb
ePub File Size: 11.38 Mb
ISBN: 983-8-70428-854-6
Downloads: 12412
Price: Free* [*Free Regsitration Required]
Uploader: Zudal

Altivar V www. Variable speed drives for asynchronous motors. Altivar Altivar Dimensions in mm width x height x depth.

Altivar – Schneider Electric T1: El variador de velocidad Altivar se integra Altivar – Sonepar www. Altivar – Botek Otomasyon B.

Altivar – Zarden. Altivar – Schneider Electric Altivar Altivar – Schneider Electric El variador de velocidad Altivar se integra maanual en sus arquitecturas y comunica con cualquier elemento de control del sistema: Altivar – inverter – plc – otomasyon B.

Variable speed drives for pumps with photovoltaic arrays. Variateurs de vitesse pour pompes Altivar – Variateur de vitesse BBV Variateurs de vitesse pour moteurs asynchrones. Variable speed drive Altivar The Altivar drive by Telemecanique is a frequency inverter for V to V Designed to make industrial and commercial machines more efficient, while at the same time simplifying its integration into a single Courtesy of Steven Engineering, Inc.

The Programacipn drive is designed to make industrial and commercial machines. Altivar 61 C1 EMC. C1 EMC from 0. Altivar Download PDF. Read and understand this manual before installing or operating the Altivar drive. The following Altivar technical documents are available on the The following special messages may appear throughout this documentation or programaccion the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.

The addition of this symbol to a Danger or Warning safety label indicates that an electrical hazard exists, which will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards.

Altivar –

Obey all safety messages that follow this symbol to avoid possible injury or death. Electrical equipment should be installed, proramacion, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product.

Installation, adjustment, repair, and maintenance must be performed by qualified personnel. Use only electrically insulated tools.

Programacion de Variadores de Velocidad Altivar ATV312

Lock all power disconnects in the open position. Failure to follow these instructions will result in death or serious injury.

  1769 OA16 PDF

Failure to follow these instructions can result in death, serious injury, or equipment damage. Examples of critical control functions are emergency stop and overtravel stop. Consideration must be given to the implications of unanticipated transmission delays or failures of the link.

The drive may be damaged if the line voltage is not compatible. Failure to follow these instructions can result in injury or equipment damage. Installation manual This manual describes how to install and wire the drive. Programming manual This manual describes the functions, parameters and use of the drive terminal integrated display terminal, optional graphic display terminal and optional remote terminal.

Simplified manual This manual is an extract from programming and installation manual. This manual is delivered with the drive. Quick Start The Quick Start describes how to wire and configure the drive to start motor quickly and simply for simple applications. This document is delivered with the drive. These manual describes the assembly, connection to the bus or network, signaling, diagnostics, and configuration of the communicationspecific parameters.

They also describe the protocol communication services. Communication variables guide The Communication variables manual defines the drive control processes and the drive variables which can be accessed by the communication buses: Receive progrramacion inspect the drive v Check that the catalog number printed on the label is the same as that on the purchase order.

Check the line voltage v Check that the voltage range of the drive is compatible with the manjal voltage see pages 10 and Steps 2 to 4 must be performed with the power off. Mount the drive v Mount the drive in accordance with the instructions in this document see page Wire the drive see page 17 v Connect the motor, ensuring that its connections correspond to the janual.

Please refer to the programming manual. Failure to follow these instructions can result in equipment damage.

The switching frequency is adjustable from 2 to 16 kHz. Above 4 kHz, the drive will reduce the switching frequency in the event of excessive temperature rise. The temperature rise is controlled by a sensor in the power module. Nonetheless, the nominal drive current should be derated if operation above 4 kHz needs to be continuous.

Derating curves are shown on page 15 as a function of switching frequency, ambient temperature and mounting conditions. Add a B at the end of the reference. Weight kg lb M3, M3 72 2. Do not place it close to heating elements. Leave sufficient free space so that the air required for cooling purposes can circulate from the bottom to the top of the unit.

Free space in front of unit: Free space u 50 mm 2 in. Drives mounted side-by-side, vent cover should be removed the degree of protection becomes IP The degree of protection becomes IP20 Note: For switching frequencies above 4 kHz and derating conditions, please refer to the derating curves for guidelines. Flow of air If you are installing the drives in enclosures, make provision for a flow of air at least equal to the value given in the table below for each drive.

  ECONOMETRIA GUJARATI DESCARGAR GRATIS PDF

Supplied with the drive Fix the EMC equipotentiality mounting plate to the holes in the ATV heatsink using the 2 screws supplied, as shown in the drawings below. Size 1 – 4 Size 5 – 7 2 screws Size 8 Size 9 2 screws 2 screws 2 screws Screws supplied: The DC bus voltage can exceed Vdc. Use a properly rated voltage-sensing device when performing this procedure. To measure the DC bus voltage: Wait 15 minutes to allow the DC bus to discharge.

If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate the drive. Where local and national codes require upstream protection by means of a residual current device, use a type A device for single-phase drives and a type B device for three-phase drives as defined in the IEC Standard Choose a suitable model integrating: The time delay is not possible for 30 mA devices; in this case, choose devices with immunity against nuisance tripping.

If the installation includes several drives, provide one lativar current device” per drive. Keep the power cables separate from circuits in the installation with low-level xe detectors, PLCs, measuring apparatus, video, telephone. If you are using cables longer than 50 m ft between the drive and the motor, add output filters please refer to the catalogue. Control Keep the control circuits away from the power cables.

For control and speed reference circuits, we recommend using shielded twisted msnual with a pitch of between 25 and 50 mm 1 and 2 in. Equipment Grounding Ground the drive according to local and national code requirements.

Use the fuses recommended in the installation manual. Use interference suppressors on all inductive circuits near the drive or coupled to the same circuit relays, contactors, solenoid valves, etc. This diagram progrsmacion for the standard ATV products. Optional communication cards may change the control wiring of the product. Please see the associated documentation for the option cards for details. Choice of associated components: Please refer to the catalogue. Accidental grounding can result in unintended activation of drive functions.

Replace the cover plate on the terminals and close the door before applying power.